Lookup Russia boiler imports under HS code 90 from Slovakia. Search boiler import data under HS code 90 from Slovakia.
Date | HS Code | Product Description | Trademark | Origin Country | Quantity | Unit | Net Weight [KGS] | Total Value [USD] | Importer Name |
---|---|---|---|---|---|---|---|---|---|
28/Sep/2017 | 9032108900 | Mechanical thermostats (Draft regulators), without the electronic control unit, without electrical drive device is designed to control the temperature in fired boilers by adjusting TYERDOTOPLIVNYH AIR FLOW THROUGH THERMOSENSITIVE Elem: TA | *** | SLOVAKIA | 1780 | *** | 1780 | 34542,07 | View Importer |
10/Sep/2017 | 9025192000 | ELECTRONIC SENSOR, DO NOT merge with other apparatuses for the central heating boiler,: the Indus. UP-TO KE of the pallet "VAILLANT" VAILLANT 0020045977 5 | *** | SLOVAKIA | 3,1 | *** | 3.1 | 209,7 | View Importer |
10/Sep/2017 | 9025198009 | NTC-sensor (sensor for detecting the current temperature), resistive, not united with other devices, are used in central heating boilers,: the Indus. UP-TO KE of the pallet "VAILLANT GMBH" VAILLANT 0020200599 10 | *** | SLOVAKIA | 0,1 | *** | 0.1 | 20,97 | View Importer |
10/Sep/2017 | 9032102000 | ELECTRONIC THERMOSTAT - DEVICE FOR AUTOMATIC. Temperature control, which is set by turning the knob on scale housing, temperature deviation of temperature sensors are fixed FROM WHICH transmits information to the electronic circuit, the COI. In the boiler CENTER. : otopl | *** | SLOVAKIA | 0,07 | *** | 0.07 | 22,13 | View Importer |
10/Sep/2017 | 9026808000 | Pitot tube - a device for measuring dynamic pressure and volume flow EXHAUST GASES central heating boilers in SOSTAVE- pitot tubes 3 pcs, PLAST.ZAGLUSHKI 5 pcs, screws and washers 3 PCS, NOT CONTAIN radioactive sources, Art. 094 282 - 10 PCS | *** | SLOVAKIA | 0,52 | *** | 0.52 | 121,48 | View Importer |
10/Sep/2017 | 9025198009 | Thermometer Turnout (Mechanical) from the sensor in the copper capillary tube (expansion of the working fluid in the capillary tube when heated, Expansion proportional heating), not united with other devices is used in boilers for central: otopl | *** | SLOVAKIA | 0,12 | *** | 0.12 | 12,63 | View Importer |
10/Sep/2017 | 9025198009 | NTC-sensor (to detect changes of temperature), non-electronic, not united with other devices, are used in central heating boilers,: the Indus. UP-TO KE of the pallet "VAILLANT GMBH" VAILLANT 103430 5 | *** | SLOVAKIA | 0,05 | *** | 0.05 | 15,79 | View Importer |
10/Sep/2017 | 9026808000 | Venturi nozzles ASSEMBLY - a device for measuring the speed and the flow rate of gases, are established on the nozzle air supply to the boiler (plastic housing, a connector for EL CABLE.), Complete with gaskets made of AFM 34, DOES NOT CONTAIN Venturi nozzles in | *** | SLOVAKIA | 0,07 | *** | 0.07 | 34,71 | View Importer |
10/Sep/2017 | 9025900008 | Of the thermometer - thermoelements (PRINCIPLE thermocouples), complete with a thin copper pipe, equipping connecting element, serves to control the flame GAS BURNER BOILER CENTRAL HEATING: The IND. UP-TO KE of the pallet " | *** | SLOVAKIA | 0,11 | *** | 0.11 | 23,86 | View Importer |
10/Sep/2017 | 9025192000 | ELECTRONIC SENSOR, not united with other devices, are designed to measure water temperature in the hydraulic circuit DIFFERENT central heating boilers,: the Indus. UP-TO KE of the pallet "VAILLANT GMBH" VAILLANT 0020068120 25 | *** | SLOVAKIA | 0,25 | *** | 0.25 | 85,57 | View Importer |
10/Sep/2017 | 9026108100 | SENSOR FOR FLOW MEASUREMENT AND FLOW FLOW WITHIN central heating boilers, non-electronic, DOES NOT CONTAIN radioactive sources, with a mounting kit, ART. 178988 -. 150 PCS, V DIS. UP-TO KE of the pallet: PRINCIPLE OF OPERATION. When the flow of | *** | SLOVAKIA | 15,75 | *** | 15.75 | 1504,09 | View Importer |
10/Sep/2017 | 9026108100 | SENSOR FOR FLOW MEASUREMENT AND FLOW FLOW WITHIN central heating boilers, electro-mechanical, with a mounting kit (2 pcs REZIN.- RING, MOUNTING BRACKET -. 2 pcs.), DOES NOT CONTAIN radioactive sources, Art. 0020014174 - 10 units: Jn. | *** | SLOVAKIA | 0,97 | *** | 0.97 | 73,28 | View Importer |
10/Sep/2017 | 9026208000 | MEASURING INSTRUMENTS - GAUGE in one housing with a thermometer with built-in copper tubing, non-electronic, DOES NOT CONTAIN radioactive sources, permanently mounted on the boiler CENTER. HEATING WITH INSTALLATION. Compl.,: The IND. UP-TO KE of the pallet Monte | *** | SLOVAKIA | 1,66 | *** | 1.66 | 284,43 | View Importer |
10/Sep/2017 | 9032102000 | Controller Electronic, NAPR.24V - DEVICE FOR AUTOMATIC. Temperature control, which is set by turning the knob on scale housing, temperature deviation of temperature sensors are fixed FROM WHICH transmits information to the electronic circuit, the COI. In the boiler: CE | *** | SLOVAKIA | 0,22 | *** | 0.22 | 68,46 | View Importer |
10/Sep/2017 | 9032200000 | Manostat electronic servo-control air pressure in the plastic case, PRENAZNACHEN for central heating boilers, Art. 0020240108 - 6 pcs., In the Indus. UP-TO KE of the pallet: HOW IT WORKS: two cavities separated by a flexible membrane, C | *** | SLOVAKIA | 0,53 | *** | 0.53 | 85,33 | View Importer |
Our market research report and Russia export statistics of boiler covers market share of Russian companies and market price of sunglass. This helps you to do market analysis on the basis of price, company, etc. perfectly and study market size of sunglass in Russia. Few shipment records with a small number of important columns from Russia export data of sunglass are given above. Other hidden fields such as Russian Exporter Name with Address, Foreign er Name with Address, Value, Quantity, Origin & Destination Country and more are also covered in Russia customs data of sunglass. To view more shipment records of sunglass export data of Russia, you can set a filter by Country Name or HS Code on the left side.
To get complete sunglass export statistics of Russia, simply fill the Request Demo Form. You can also drop your queries through info@exportgenius.in or +91-11-47048012.
Are you looking for Russia buyers or importers of boiler